Manufactured entirely from 100% recycled plastics in the UK, this Ecolite Duct Access Chamber offers a swift, eco-conscious alternative to traditional concrete or brick structures. Its 150mm deep rings effortlessly interlock, enabling a seamless load-bearing assembly without t... Read More
SUPER Rewards Earn points and build more across our SUPERSTORES!
Find out moreManufactured entirely from 100% recycled plastics in the UK, this Ecolite Duct Access Chamber offers a swift, eco-conscious alternative to traditional concrete or brick structures. Its 150mm deep rings effortlessly interlock, enabling a seamless load-bearing assembly without the need for complex construction.
Suitable for both pedestrian walkways and roadways, this Ecolite system has undergone rigorous testing, meeting the standards of BSEN124 B125 and D400 loadings. Its innovative twin-wall design incorporates internal support ribs, granting the chamber remarkable durability while eliminating the necessity for a concrete surround in most scenarios.
Lightweight yet robust, this system significantly minimises health and safety risks for on-site workers. Additionally, it can be conveniently drilled on-site for streamlined duct entries, ensuring a hassle-free installation process.
Question:
What is the external size length x width of each section?
Answer:
The external sizes of this Chamber are 780mm x 630mm
Question:
What are the external dimensions for a 900mm x 900mm chamber?
Answer:
The external frame size of this chamber is 1100mm x 1100mm.
Question:
Are these or can these be made water resistant to avoid the chamber filling with water?
Answer:
These chambers are water resistant to a certain extent. This all depends on the installation of the chambers, the depth and the cover that you use with it.
Question:
What is the lid that covers the top ?
Answer:
You would need any 1200 x 900mm manhole cover.
Question:
Hi are these fibre glass
Answer:
They are made out of Recycled Polypropylene.
Question:
Hi what depth can these access chambers be used to?
Answer:
This would depend on what weight is needing to go over them.
Question:
Please confirm that the Ecolite Duct Access Chamber would be compatible with Clark Manhole Cover CD 752 KMB in terms of fit.
Answer:
Yes this would be suitable
Question:
What is the maximum depth the following product can be used for without reinforcement?
Answer:
This can go to 2 metres depth. If you need to go deeper, we would need to know what would be going over them.